Building Facade Inspection Checklist
69 questions in 12 sectionsInteractive preview: try the answers
Section 1 of 12 · 7 questionsCladding And External Finishes
All cladding panels are fully seated with no visible displacement, bowing, or deformation
Visible panel fixings and brackets show no signs of corrosion or mechanical failure
Render finish is intact with no cracking, hollowness, or delamination evident
Sealant joints between panels and at perimeter conditions are continuous and free from splitting or debonding
Weep holes are present and clear of obstruction at the base of cladding zones
No visible gaps are present between cladding panels and the surrounding structure
Material type and approximate coverage area of cladding are recorded
Section 2 of 12 · 5 questionsDrainage And Waterproofing
Gutters and rainwater goods are securely fixed, free from blockages, and discharging correctly
Downpipes are intact, unobstructed, and discharging to a suitable outlet
Parapet and flat roof drainage outlets are clear and free from debris
No visible damp patches, tide marks, or water ingress staining are present on internal surfaces adjacent to the facade
Ground-level drainage channels and gullies are clear and functioning
Section 3 of 12 · 5 questionsHealth, Safety And Access
Appropriate PPE is worn for all inspection activities, including hard hat, hi-vis, and safety footwear
Pedestrian exclusion zones are in place beneath any elevated access equipment
Scaffold, MEWP, or rope access equipment has a current inspection certificate
Residents and occupants have been notified of the inspection in advance
Public protection measures (hoarding, barriers, signage) are in place where required
Section 4 of 12 · 5 questionsPhase 1 Findings Summary And Intrusive Trigger
All defects observed during Phase 1 have been photographed and recorded with elevation and height references
A severity classification (routine maintenance, monitor, or urgent action) has been assigned to each defect
Assessment of whether findings warrant intrusive investigation has been completed and recorded
Zones identified for potential opening-up are marked on an elevation drawing
The building owner or responsible person has been informed of Phase 1 findings before Phase 2 proceeds
Section 5 of 12 · 5 questionsPre-inspection Setup
As-built drawings, previous inspection reports, and maintenance records have been reviewed before attending site
The scope and zone coverage for this inspection has been confirmed and documented
A safe method of access has been identified for all facade elevations
Risk assessment and method statement (RAMS) are in place and signed off
All persons conducting the inspection have been briefed on site-specific hazards
Section 6 of 12 · 7 questionsSurface Condition — Masonry And Concrete
External masonry is free from cracks wider than 1 mm
No active spalling, delamination, or loose material is visible on any elevation
Movement joints are intact, unobstructed, and free from cracking or sealant failure
Mortar joints are sound, with no evidence of erosion, hollowness, or missing pointing
Concrete surfaces show no signs of carbonation, exposed reinforcement, or rust staining
Staining patterns (water tracks, efflorescence, biological growth) are recorded with photographs and location noted
Location, orientation, and width of all visible cracks are recorded as a free-form field
Section 7 of 12 · 5 questionsWindows, Doors And Penetrations
Window and door frames show no signs of corrosion, distortion, or seal failure
Glazing units are intact with no cracking, crazing, or broken panes
Sill drainage is unobstructed and directing water clear of the facade
Service penetrations (pipes, conduits, cables) through the external wall are fully sealed at the perimeter
Cavity trays and flashings at openings are visible where accessible and appear intact
Section 8 of 12 · 5 questionsBuild-up Verification — Cladding And Outer Leaf
The outer cladding material has been identified and its generic classification recorded
Material type, manufacturer, and product reference are recorded where visible
The fixing system matches the design intent or as-built records
No unintended voids or air gaps are present within the cladding layer
The substrate or backing wall has been identified and its condition recorded
Section 9 of 12 · 5 questionsBuild-up Verification — Insulation And Membranes
Insulation material has been identified and its generic classification recorded
Insulation product type, thickness, and continuity are recorded
No unplanned gaps, compression damage, or missing sections are present
Breather membrane or vapour control layer is continuous and correctly installed
Sheathing boards are present, correctly fixed, and joints sealed
Section 10 of 12 · 8 questionsCavity Barriers And Fire Stopping
Cavity barriers are present at all required locations
Cavity barrier material is appropriate
Cavity barriers are correctly fitted and free from gaps
Cavity barriers are continuous at junctions
Fire stopping is present and intact at service penetrations
Fire stopping at compartment floor junctions is correctly installed
Deficiencies have been photographed and precisely recorded
Overall assessment of cavity barriers and fire stopping has been recorded
Section 11 of 12 · 6 questionsMaking Good And Investigation Documentation
All openings have been reinstated using compatible materials
Photographic records have been taken before, during, and after making good
Each photograph is labelled with required references
A written record of findings has been completed for each opening
Findings support a FRAEW under PAS 9980:2022 or a remediation brief
The responsible person or building owner has been briefed on completion
Section 12 of 12 · 6 questionsOpening-up Scope And Preparation
The number, location, and elevation zones of openings have been agreed and marked on drawings before works commence
Opening locations are selected to target representative zones, including floor lines, window heads, corners, and areas of Phase 1 concern
A minimum of one opening per distinct facade type or construction zone has been planned
Residents and occupants in affected areas have been notified and access arrangements confirmed
Working-at-height controls, including scaffold or rope access inspection certificates, are current and in place
The scope of making-good works and materials for reinstatement has been confirmed before opening up
Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.
Free PDF
Download the Building Facade Inspection Checklist
By downloading this checklist you agree to the GoAudits privacy policy and terms of service.
NEW! Try generating a custom checklist with our free AI tool:
Easy inspection app for your digital checklists
- Conduct inspections anytime, anywhere - even offline
- Capture photos as proof of compliance or areas needing attention
- Instantly generate and share detailed reports after the inspections
- Assign & track follow-up tasks, view historical trends on a centralized dashboard