Building Facade Inspection Checklist

Use this Building Facade Inspection Checklist to inspect surface condition, structural elements, drainage, and intrusive investigation of cladding build-up and fire stopping.

Building Facade Inspection Checklist



Cladding And External Finishes

1. All cladding panels are fully seated with no visible displacement, bowing, or deformation


Photo Comment

2. Visible panel fixings and brackets show no signs of corrosion or mechanical failure


Photo Comment

3. Render finish is intact with no cracking, hollowness, or delamination evident


Photo Comment

4. Sealant joints between panels and at perimeter conditions are continuous and free from splitting or debonding


Photo Comment

5. Weep holes are present and clear of obstruction at the base of cladding zones


Photo Comment

6. No visible gaps are present between cladding panels and the surrounding structure


Photo Comment

7. Material type and approximate coverage area of cladding are recorded


Photo Comment
Drainage And Waterproofing

1. Gutters and rainwater goods are securely fixed, free from blockages, and discharging correctly


Photo Comment

2. Downpipes are intact, unobstructed, and discharging to a suitable outlet


Photo Comment

3. Parapet and flat roof drainage outlets are clear and free from debris


Photo Comment

4. No visible damp patches, tide marks, or water ingress staining are present on internal surfaces adjacent to the facade


Photo Comment

5. Ground-level drainage channels and gullies are clear and functioning


Photo Comment
Health, Safety And Access

1. Appropriate PPE is worn for all inspection activities, including hard hat, hi-vis, and safety footwear


Photo Comment

2. Pedestrian exclusion zones are in place beneath any elevated access equipment


Photo Comment

3. Scaffold, MEWP, or rope access equipment has a current inspection certificate


Photo Comment

4. Residents and occupants have been notified of the inspection in advance


Photo Comment

5. Public protection measures (hoarding, barriers, signage) are in place where required


Photo Comment
Phase 1 Findings Summary And Intrusive Trigger

1. All defects observed during Phase 1 have been photographed and recorded with elevation and height references


Photo Comment

2. A severity classification (routine maintenance, monitor, or urgent action) has been assigned to each defect


Photo Comment

3. Assessment of whether findings warrant intrusive investigation has been completed and recorded


Photo Comment

4. Zones identified for potential opening-up are marked on an elevation drawing


Photo Comment

5. The building owner or responsible person has been informed of Phase 1 findings before Phase 2 proceeds


Photo Comment
Pre-inspection Setup

1. As-built drawings, previous inspection reports, and maintenance records have been reviewed before attending site


Photo Comment

2. The scope and zone coverage for this inspection has been confirmed and documented


Photo Comment

3. A safe method of access has been identified for all facade elevations


Photo Comment

4. Risk assessment and method statement (RAMS) are in place and signed off


Photo Comment

5. All persons conducting the inspection have been briefed on site-specific hazards


Photo Comment
Surface Condition — Masonry And Concrete

1. External masonry is free from cracks wider than 1 mm


Photo Comment

2. No active spalling, delamination, or loose material is visible on any elevation


Photo Comment

3. Movement joints are intact, unobstructed, and free from cracking or sealant failure


Photo Comment

4. Mortar joints are sound, with no evidence of erosion, hollowness, or missing pointing


Photo Comment

5. Concrete surfaces show no signs of carbonation, exposed reinforcement, or rust staining


Photo Comment

6. Staining patterns (water tracks, efflorescence, biological growth) are recorded with photographs and location noted


Photo Comment

7. Location, orientation, and width of all visible cracks are recorded as a free-form field


Photo Comment
Windows, Doors And Penetrations

1. Window and door frames show no signs of corrosion, distortion, or seal failure


Photo Comment

2. Glazing units are intact with no cracking, crazing, or broken panes


Photo Comment

3. Sill drainage is unobstructed and directing water clear of the facade


Photo Comment

4. Service penetrations (pipes, conduits, cables) through the external wall are fully sealed at the perimeter


Photo Comment

5. Cavity trays and flashings at openings are visible where accessible and appear intact


Photo Comment
Build-up Verification — Cladding And Outer Leaf

1. The outer cladding material has been identified and its generic classification recorded


Photo Comment

2. Material type, manufacturer, and product reference are recorded where visible


Photo Comment

3. The fixing system matches the design intent or as-built records


Photo Comment

4. No unintended voids or air gaps are present within the cladding layer


Photo Comment

5. The substrate or backing wall has been identified and its condition recorded


Photo Comment
Build-up Verification — Insulation And Membranes

1. Insulation material has been identified and its generic classification recorded


Photo Comment

2. Insulation product type, thickness, and continuity are recorded


Photo Comment

3. No unplanned gaps, compression damage, or missing sections are present


Photo Comment

4. Breather membrane or vapour control layer is continuous and correctly installed


Photo Comment

5. Sheathing boards are present, correctly fixed, and joints sealed


Photo Comment
Cavity Barriers And Fire Stopping

1. Cavity barriers are present at all required locations


Photo Comment

2. Cavity barrier material is appropriate


Photo Comment

3. Cavity barriers are correctly fitted and free from gaps


Photo Comment

4. Cavity barriers are continuous at junctions


Photo Comment

5. Fire stopping is present and intact at service penetrations


Photo Comment

6. Fire stopping at compartment floor junctions is correctly installed


Photo Comment

7. Deficiencies have been photographed and precisely recorded


Photo Comment

8. Overall assessment of cavity barriers and fire stopping has been recorded


Photo Comment
Making Good And Investigation Documentation

1. All openings have been reinstated using compatible materials


Photo Comment

2. Photographic records have been taken before, during, and after making good


Photo Comment

3. Each photograph is labelled with required references


Photo Comment

4. A written record of findings has been completed for each opening


Photo Comment

5. Findings support a FRAEW under PAS 9980:2022 or a remediation brief


Photo Comment

6. The responsible person or building owner has been briefed on completion


Photo Comment
Opening-up Scope And Preparation

1. The number, location, and elevation zones of openings have been agreed and marked on drawings before works commence


Photo Comment

2. Opening locations are selected to target representative zones, including floor lines, window heads, corners, and areas of Phase 1 concern


Photo Comment

3. A minimum of one opening per distinct facade type or construction zone has been planned


Photo Comment

4. Residents and occupants in affected areas have been notified and access arrangements confirmed


Photo Comment

5. Working-at-height controls, including scaffold or rope access inspection certificates, are current and in place


Photo Comment

6. The scope of making-good works and materials for reinstatement has been confirmed before opening up


Photo Comment