Section 1 of 7 · 12 questionsGeneral Facility Water Management—Monitoring And Education
Are water meters read and is monthly water use recorded? Is it verified that all meters and submeters are installed properly?
Are water and cost savings tracked over time in utility management systems?
Are submeters installed on all major water-using equipment, systems, or processes (e.g., cooling towers, tenant spaces, irrigation systems, single-pass cooling, and HVAC systems)?
Is leak detection and repair included in all operation and maintenance (O&M) programs?
Are staff and visitors instructed with clear signage on how and where to report leaks at all points of water use?
Are facility staff, building occupants, employees, and visitors educated on water management program goals and initiatives?
Are water-efficient best management practices (BMPs) incorporated into all Standard Operating Procedures (SOPs) for O&M throughout the facility, including those for maintenance and cleaning staff?
Has a green team been formed to engage employees in saving water throughout the building?
Are water efficiency criteria incorporated into procurement policies along with energy efficiency?
Are employees educated to turn off equipment, including all continuous flow equipment, between uses? Are automatic shut-off valves used where applicable?
Are employees educated to use “dry” cleaning methods to avoid washing down equipment or areas with a water hose or mop? Are sweeping or mopping methods used instead of spray washing with water?
Is water pressure tested regularly on each floor of the facility to ensure it is within the optimal range for fixture and equipment performance? Are pressure-regulating valves used to correct any issues (i.e., the optimal pressure is between 20 and 80 psi for most fixtures)?
Section 2 of 7 · 16 questionsSanitary Fixtures And Equipment
Are all fixtures and valves regularly checked for scaling and cleaned as needed?
Are all automatic- and sensor-flushing devices tested and calibrated regularly to prevent double/phantom flushes?
Are tank-type toilets regularly checked for leaks, broken flappers, and other part failures?
Is instructional signage displayed with all dual-flush devices to ensure proper use?
Have old tank-type and flushometer-valve toilets been replaced with models that flush at 1.28 gpf or less?
Have old flushing urinals been replaced with models flushing at 0.5 gpf or less?
Are automatic sensors and metering faucets regularly checked and adjusted to ensure accurate timing and water delivery per cycle?
Have all lavatory faucets or faucet aerators in private-use restrooms (e.g., hotel guest rooms, dorms, and hospital patient rooms) been replaced with models that flow at 1.5 gallons per minute (gpm) or less?
Have old lavatory faucets or faucet aerators in public-use restrooms been replaced with 0.5 gpm models or metered faucets that deliver no more than 0.25 gallons per cycle?
Have old showerheads been replaced with models that flow at 2.0 gpm or less?
Are only full loads of laundry washed?
Are clothes washers programmed to use the lowest amount of water, detergent, and chemicals necessary?
Are wash cycles and detergent/chemical formulations evaluated for maximum efficiency (i.e., the least number of wash and rinse cycles)?
Have clothes washers been retrofitted with water reuse or recycling systems?
Have clothes washers been retrofitted with ozone injection systems?
Have old single-load clothes washers been replaced with proper models? Has a lower water factor been considered when purchasing larger commercial or industrial-sized laundry machines?
Section 3 of 7 · 42 questionsCommercial Kitchen Equipment
Is signage placed at all major points of water use to remind employees to turn off taps and report leaks?
Is all continuous flow equipment shut down or put in standby mode between uses?
Have automatic shutoffs been installed so water doesn’t run when garbage disposals or faucets are not in use?
Is running water avoided when melting unwanted ice or thawing frozen food? Are alternative methods such as refrigeration, microwaves, or water baths used instead?
Have aerators been installed on all kitchen handwashing sinks?
Are faucets, dishwashers, steam equipment, and other kitchen equipment regularly checked for leaks?
Have ice machines that are cooled with single-pass cooling water been eliminated or replaced? Have retrofits been installed to distribute chilled water or use air-cooled models instead?
Are coils on the heat exchange unit of an ice machine regularly cleaned to maintain efficiency?
Is ice shape and quality matched to its intended use? Are equipment models that produce flaked ice used instead of cubes whenever possible?
Are ice machines periodically cleaned to remove lime and scale buildup? Are they sanitized to kill bacteria and fungi?
Has a timer been installed to shift ice production to nighttime or off-peak hours to reduce peak energy demand?
Are ice machine rinse cycles set to the lowest possible frequency while still maintaining sufficient ice quality? If available, is a sensor used to initiate the rinse cycle based on mineral content?
Are lids kept closed to retain cool air inside ice machines and maintain appropriate temperature?
Have old ice machines been replaced with certified models?
Are steam cookers, steam kettles, and combination ovens loaded to capacity? Are only the necessary compartments used?
Are doors and lids kept closed on all steam equipment while in operation?
Are gaskets replaced and hinges tightened on steam equipment doors to ensure a good seal and retain heat or steam?
Is the use of steam and combi-mode minimized? Is hot air or convection mode used whenever possible?
Are ovens, cookers, and kettles turned off or down during slow times or when not in use? Are timers used to return them to standby mode after use? Is standby mode only used when necessary?
Has a condensate return system been considered to reduce potable water needed for make-up water in boiler-based equipment?
Have connectionless combination ovens, steam cookers, and steam kettles been installed whenever possible?
Are equipment cooling water lines routinely checked for leaks and corrosion? Are shutoff valves inspected to ensure proper functioning?
Have old steam cookers and combination ovens been replaced with certified models?
Have old water-cooled wok stoves been replaced with waterless models?
Have in-line flow restrictors been installed to reduce dipper wells’ flow rate to 0.3 gpm or less?
Has a push-button metering faucet or under-counter dishwasher been installed to clean utensils instead of using dipper wells?
Are employees trained to use always-on clamps on pre-rinse spray valves only when necessary? Are they encouraged to report leaks and broken/loose parts?
Have old, inefficient pre-rinse spray valves been replaced with models that flow at 1.28 gpm or less?
Is food hand-scraped from dishes or are food strainers installed, and are the scraps used for composting food waste?
Is water turned off to food disposal systems during idle periods and when the kitchen is closed? Has a timer been installed to stop the flow after 15 minutes, requiring users to reactivate it periodically?
Are disposal systems operated to run only cold water to minimize hot water and energy use?
Have disposal systems been retrofitted with load sensors to regulate water use based on the disposal motor’s load, reducing idle flow rate?
Have food disposals been replaced with food pulpers or strainers to minimize water use?
Is water extracted and recirculated within the food disposal system to use for pre-rinsing dishes or sluice troughs instead of potable water?
Are dishwashers loaded to capacity before running?
Is the dishwasher run at or close to the minimum flow rate and rinse cycle time recommended by the manufacturer? Is the final rinse pressure and water temperature verified to be within manufacturer recommendations?
Do manual fill valves close completely after the wash tank is full? Are valves and rinse nozzles inspected and repaired periodically?
For conveyor-type dishwashing machines, is the rinse bypass drain adjusted so the wash tank is properly replenished during dishwashing operation?
Have wash curtains been installed to retain heat in conveyor-type dishwashing machines? Are conveyor-type machines operated in auto-mode to save energy?
Have old dishwashers been replaced with certified models?
Do wash-down sprayers have a self-closing nozzle, and are they shut off when not in use?
Is a broom or mop used instead of a wash-down sprayer to clean floors when possible? Are pressure washers or water brooms used when water is needed?
Section 4 of 7 · 34 questionsOutdoor Water Use
Are native or drought-tolerant species planted?
Is mulch (3") used around trees and plant beds?
Are landscape professionals who are trained and certified in water-efficient or climate-appropriate landscaping hired?
Are water, chemical, and energy-efficient requirements incorporated into all landscape and irrigation service and maintenance agreements?
Is 4" to 6" of good topsoil maintained to capture and release precipitation back to plants over time?
Is soil composition balanced with topsoil or compost to restore water-holding capacity and proper drainage?
Are weeds removed from irrigated landscapes so water is available for desired landscaping? Are weeds pulled manually instead of using herbicides?
Is the blade on mowers raised to allow grass to grow longer and become more drought-resistant?
Is turfgrass allowed to turn brown during dry periods if the species will recover when rainfall returns?
Are additional trees and shrubbery planted to increase shaded areas?
Is turfgrass limited to areas with functional purposes such as erosion control or recreation?
Is "strip grass," or small, disconnected patches of grass, avoided since they are hard to maintain and difficult to water efficiently?
Are plants with similar irrigation needs grouped together to enable effective watering using hydrozoning techniques?
Have labeled weather-based irrigation controllers been installed, or have irrigation controllers with rain or soil moisture sensors been considered instead of using clock timers?
Is drip irrigation used to water plant beds, trees, and shrubs?
Is the irrigation schedule appropriate for climate, soil conditions, plant materials, grading, and the season?
Has an irrigation professional certified by a labeled program conducted a full audit of the irrigation system within the last three years?
Are all irrigation system parts and components regularly inspected and repaired as part of standard maintenance procedures? Are all broken sprinkler heads repaired immediately?
Is the position and location of sprinkler heads checked to ensure they are working properly and not directing water onto non-landscaped areas such as sidewalks?
Is the landscape visually inspected for water pooling or puddling regularly to prevent plant damage from overwatering?
Is irrigation scheduling adjusted frequently to reflect actual site conditions, including climate, soil conditions, plant materials, grading, and the season?
Are the intensity and frequency of watering schedules adjusted to fit soil types and landscape features, encouraging deep watering and deep root growth for healthier plants?
Has a separate meter been installed to measure irrigation water use? Is it monitored regularly to detect leaks and other issues?
Has the local wastewater utility been contacted to check for available credits for water applied to landscaping rather than being discharged into the sewer system?
Are alternative water sources used for irrigation and decorative water features instead of potable water?
Is water recirculated in decorative fountains, ponds, and waterfalls, and is non-potable water used in these systems when possible?
Are water features shut off when possible to reduce evaporation losses? Are recirculation systems checked annually for leaks and other damage?
Are sidewalks, driveways, parking lots, tennis courts, pool decks, and other hardscapes swept instead of hosed down? Are water brooms used for greater time and water efficiency?
Are pools kept below 79°F to minimize evaporation?
Are pool covers or liquid barriers used to control evaporation loss?
Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.
Free PDF
Download the Water Audit Checklist
By downloading this checklist you agree to the GoAudits privacy policy and terms of service.
NEW! Try generating a custom checklist with our free AI tool:
Easy inspection app for your digital checklists
- Conduct inspections anytime, anywhere - even offline
- Capture photos as proof of compliance or areas needing attention
- Instantly generate and share detailed reports after the inspections