Tile Work Inspection Checklist for Floor and Wall Tiling

Tile Work Inspection Checklist for QA teams and site engineers to check substrate prep, adhesive coverage, lippage, grout, and wall tiling before handover.

Tile Work Inspection Checklist for Floor and Wall Tiling



50 questions in 9 sectionsInteractive preview: try the answers

Section 1 of 9 · 6 questions

Documentation And Approvals

  1. Tile type, size, and finish match the approved sample and specification

  2. Adhesive and grout products match the specification for the substrate and area

  3. Tile batch and shade numbers are recorded for each area

  4. Waterproofing membrane in wet areas is inspected and signed off before tiling

  5. Tile layout drawing showing setting-out points and joint positions is approved

  6. Preceding trades in the area (plumbing, electrical, plastering) are signed off

Section 2 of 9 · 4 questions

Materials On Site

  1. Tiles are stored dry, flat, and protected from damage

  2. Delivered tiles are checked for chips, cracks, and warping before use

  3. Adhesive and grout bags are sealed, dry, and within their use-by date

  4. Specified trims, spacers, and leveling clips are on site in sufficient quantity

Section 3 of 9 · 7 questions

Substrate Preparation

  1. Substrate is clean and free of dust, laitance, grease, and loose material

  2. Substrate is sound, with no cracks, hollow render, or flaking areas

  3. Concrete, screed, or render has cured for the period set in the specification

  4. Substrate flatness is within the specified tolerance when checked with a straightedge

  5. Primer is applied where the adhesive manufacturer requires it

  6. Floor drains, pipe penetrations, and outlet boxes are fixed at final level

  7. Floor screed in wet areas falls toward drains

Section 4 of 9 · 4 questions

Setting Out

  1. Datum and level lines are marked on walls and floors

  2. Layout avoids narrow cut tiles at edges, doorways, and openings

  3. Wall and floor joint lines are planned to align where specified

  4. First course of wall tiles is set level from a fixed batten or line

Section 5 of 9 · 6 questions

Laying In Progress

  1. Adhesive is mixed to the manufacturer's ratio and used within its pot life

  2. Notched trowel size suits the tile format and substrate

  3. Large-format tiles are back-buttered in addition to troweled adhesive

  4. A lifted tile shows adhesive coverage meeting the specified minimum

  5. Spacers or a leveling system keep joint widths consistent

  6. Movement joints are placed at perimeters, over structural joints, and at specified intervals

Section 6 of 9 · 6 questions

Wall Tiling

  1. Wall tiles are plumb and true when checked with a straightedge and level

  2. Horizontal joints run level and vertical joints run plumb

  3. External corners are finished with the specified trim or a clean miter

  4. Cuts around switches, outlets, and pipes are neat and covered by plates or escutcheons

  5. No hollow areas are found when wall tiles are tapped

  6. Splashback and wainscot heights match the drawings

Section 7 of 9 · 7 questions

Floor Tiling

  1. Floor surface is flat within the specified tolerance over a straightedge

  2. Lippage between adjacent tiles is within the specified tolerance

  3. Floor falls to drains with no ponding during a flood test

  4. No hollow areas are found when floor tiles are tapped

  5. Floor joints align with skirting and wall tile joints where specified

  6. Thresholds and transitions to other floor finishes are flush or trimmed as specified

  7. Slip resistance rating of floor tiles suits wet, external, and ramped areas

Section 8 of 9 · 5 questions

Grout, Sealant, And Movement Joints

  1. Grout type and color match the approved specification

  2. Grout joints are fully filled, even, and free of pinholes and cracks

  3. Internal corners and changes of plane are sealed with flexible sealant, not grout

  4. Sealant is continuous around baths, shower trays, basins, and pipe penetrations

  5. Movement joints are free of grout and filled with the specified sealant

Section 9 of 9 · 5 questions

Finish And Protection

  1. No chipped, cracked, or damaged tiles are visible from a standing position

  2. Tile surfaces are free of grout haze, adhesive smears, and paint drips

  3. Shade and pattern are consistent across the area, with no visible batch variation

  4. Finished floors are protected and closed to traffic until the grout has cured

  5. Spare tiles from the same batch are labeled and handed over to the client

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.

Free PDF

Download the Tile Work Inspection Checklist for Floor and Wall Tiling

By downloading this checklist you agree to the GoAudits privacy policy and terms of service.

NEW! Try generating a custom checklist with our free AI tool:

Easy inspection app for your digital checklists