Pre-Drywall Inspection Checklist

Use the Pre-Drywall Inspection Checklist for a thorough assessment before finalizing construction, ensuring structural integrity and compliance.

Pre-Drywall Inspection Checklist



Pre-Drywall Inspection

1. Have all walls been checked for plumb and square?


Photo Comment

2. Have bowed and twisted studs been checked for?


Photo Comment

3. Have all blocking elements, including ADA handrails, cabinets, balcony rails, stair rails, etc., been checked?


Photo Comment

4. Have all draft stop vertical and horizontal elements been checked?


Photo Comment

5. Has the subfloor been checked for damage and/or soft spots?


Photo Comment

6. Have approved point load locations been confirmed?


Photo Comment

7. Has the material for fire ratings and sill treatment been confirmed?


Photo Comment

8. Have door and window locations/opening sizes been confirmed and coordinated with the floor thickness system?


Photo Comment

9. Have windows been checked for proper installation and ease of operation?


Photo Comment

10. Have ADA/ANSI unit requirements and dimensions been confirmed?


Photo Comment

11. Has the proper installation of structural hardware, including hangers, straps, anchors, bolts, CLP, compression post, etc., been confirmed?


Photo Comment

12. Have header and beam locations, type, and installation (cripples and king studs) been confirmed?


Photo Comment

13. Have wall types, sheer wall locations, and construction been confirmed?


Photo Comment

14. Has the building been cleaned and swept?


Photo Comment

15. Is the framing inspection complete, both by the city official and the structural engineer?


Photo Comment

16. Are all walls straight-edged and planed?


Photo Comment
Electrical

1. Has the electrical inspection been performed and approved?


Photo Comment

2. Are all the nail plates correctly installed?


Photo Comment

3. Has the fire protection been installed around all conduit/MC cables above ceilings and walls?


Photo Comment

4. Is all the gypsum board in fire-rated partitions, due to electrical conduit/MC cable installation, free from damage?


Photo Comment

5. Is all blocking used by subcontractors complete?


Photo Comment

6. Do all boxes have the proper support ears for the partition type they are in, secure, and in the right location?


Photo Comment
Plumbing

1. Has the plumbing inspection been performed and approved?


Photo Comment

2. Have all the water lines been tested?


Photo Comment

3. Has fire protection been installed around all plumbing lines above ceilings in fire-rated partitions?


Photo Comment

4. Are all plumbing lines strapped correctly?


Photo Comment

5. Are all nail plates correctly installed?


Photo Comment

6. Is all gypsum board in fire-rated partitions, due to piping installation, free from damage?


Photo Comment

7. Is any and all blocking used by subcontractors correctly installed?


Photo Comment
Sprinkler

1. Has the sprinkler inspection been performed?


Photo Comment

2. Have all penetrations through fire-rated partitions above ceiling level had fire protection installed?


Photo Comment

3. Have all sprinkler lines been tested?


Photo Comment

4. Have all sprinkler heads been capped off?


Photo Comment

5. Has water been placed into the system, tested at 200 PSI for 2 hours, and held?


Photo Comment
HVAC

1. Has the HVAC inspection been performed?


Photo Comment

2. Have all penetrations through fire-rated partitions above the ceiling level have fire protection installed?


Photo Comment

3. Have all ducts penetrating exterior walls been properly sealed?


Photo Comment

4. Are all duct supply drops and returns in the correct area?


Photo Comment

5. Are all flex ducts properly secured?


Photo Comment

6. Have line sets been run and tested?


Photo Comment

7. Are all condensate drains sloped and completed?


Photo Comment
Low Voltage

1. Has the low voltage inspection been performed?


Photo Comment

2. Is the SOHO box installed and in the proper location?


Photo Comment

3. Are all penetrations properly fire-sealed?


Photo Comment

4. Are all boxes in the correct location and secure?


Photo Comment

5. Is all gypsum board in fire-rated partitions, due to wiring installation, free from damage?


Photo Comment
Insulation

1. Is all Rock Wool in place for fire blocking on Party Walls?


Photo Comment

2. Is all Rock Wool in place on Plumbing Walls where needed?


Photo Comment

3. Is Rock Wool in place under the Tub Drain?


Photo Comment

4. Is all insulation in ceilings and walls installed with the proper R-value?


Photo Comment
General

1. Have all trade inspections been accounted for?


Photo Comment

2. Is all blocking and/or strapping in fire-rated partitions fire-rated wood?


Photo Comment

3. Have all windows been waterproofed?


Photo Comment

4. Is the unit broom clean and ready for the final walk-through?


Photo Comment