HVAC Commissioning Checklist

Use this HVAC Commissioning Checklist as a report template to ensure proper system installation and verify control units, coils, and system operations.

HVAC Commissioning Checklist



35 questions in 7 sectionsInteractive preview: try the answers

Section 1 of 7 · 12 questions

Programmable Thermostats

  1. Is the installation carried out according to the manufacturer's instructions?

  2. Is the programming done according to the designed control strategy?

  3. Is the heating operation verified during occupied periods?

  4. Is the heating operation verified during unoccupied periods?

  5. Is the cooling operation verified during occupied periods?

  6. Is the cooling operation verified during unoccupied periods?

  7. Is the system operation verified during occupied hours under no-load conditions?

  8. Is the system operation verified during unoccupied hours under no-load conditions?

  9. Is the system status verified when power is lost?

  10. Is the system operation verified when power is returned?

  11. Is the battery backup verified?

  12. Are the room temperatures measured for compliance with the set point?

Section 2 of 7 · 5 questions

Installation

  1. Is the refrigerant pipe leak tested?

  2. Is the refrigerant pipe evacuated and charged following the manufacturer's instructions?

  3. Are the condenser fans for proper rotation checked?

  4. Is the damage to the coil fins repaired?

  5. Is the manufacturer's required maintenance/operational clearance provided?

Section 3 of 7 · 3 questions

Electrical

  1. Is power available to the unit disconnected?

  2. Is power available to the unit control panel?

  3. Is the power disconnect verified to be located within sight of the unit it controls?

Section 4 of 7 · 3 questions

Controls

  1. Are the safety/protection devices of the unit tested?

  2. Are the control system and interlocks installed?

  3. Are the control system and the interlocks operational?

Section 5 of 7 · 3 questions

Testing, Adjusting, And Balancing (TAB)

  1. Is the terminal maximum airflow set verified?

  2. Is the terminal minimum airflow set verified?

  3. Is the TAB (Testing, Adjusting, and Balancing) operation completed?

Section 6 of 7 · 6 questions

Coils

  1. Is the chilled water piping properly connected?

  2. Is the chilled water piping pressure tested?

  3. Is the hot water piping properly connected?

  4. Is the hot water piping pressure tested?

  5. Are air vents installed on water coils with shutoff valves as specified?

  6. Is any damage to the coil fins repaired?

Section 7 of 7 · 3 questions

Heat Recovery Unit

  1. Are the controls operable?

  2. Is the power connected, and the rotation checked?

  3. Are the bypass dampers operable?

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.

Free PDF

Download the HVAC Commissioning Checklist

By downloading this checklist you agree to the GoAudits privacy policy and terms of service.

NEW! Try generating a custom checklist with our free AI tool:

Easy inspection app for your digital checklists