SQF Module 11 GMP Checklist (Edition 10)

SQF Module 11 GMP checklist for Edition 10 food manufacturing. Inspect premises, cleaning, pests, hygiene, storage, transport, and foreign matter.

SQF Module 11 GMP Checklist (Edition 10)



256 questions in 14 sectionsInteractive preview: try the answers

Section 1 of 14 · 36 questions

11.1 Site Location And Premises

  1. Documented risk assessments cover local activities, clothing and jewelry, temporary storage, and overhead ducting and pipes (11.1.1.1)

  2. Premises risk assessments are reviewed yearly or when changes occur (11.1.1.1)

  3. Floors are smooth, impervious, easy to clean, and sloped to drains so water does not pool (11.1.2.1)

  4. Where floor drains are absent, plumbed options handle overflow and wastewater (11.1.2.1)

  5. Waste traps are located away from food handling areas and entrances (11.1.2.2)

  6. Walls, partitions, doors, and hatches are durable, impervious, and light-colored (11.1.2.3)

  7. Wall-to-wall and wall-to-floor junctions are sealed to prevent debris build-up (11.1.2.3)

  8. Ducting, conduit, and overhead pipes do not contaminate food and are easy to clean (11.1.2.4)

  9. Windows in processing, handling, and storage areas are shatterproof (11.1.2.5)

  10. External windows, doors, and openings seal when closed and are dust proofed (11.1.2.5)

  11. Product areas have a ceiling or structure that prevents contamination (11.1.2.6)

  12. Drop ceilings allow pest monitoring, cleaning, and access to utilities (11.1.2.6)

  13. Stairs, catwalks, and platforms do not create a contamination risk (11.1.2.7)

  14. There are no open grates directly above exposed product (11.1.2.7)

  15. Lighting is bright enough for tasks and meets local requirements or industry standards (11.1.3.1)

  16. Light fixtures over exposed product are shatterproof or covered, and recessed or flush (11.1.3.2)

  17. Non-recessed fixtures over exposed product are protected from breakage and cleanable (11.1.3.2)

  18. Light fixtures over covered product are designed to prevent breakage and contamination (11.1.3.3)

  19. Where on-line inspection is required, the area has handwashing access, waste handling, and is clean (11.1.4.1)

  20. Enclosed processing areas are adequately ventilated, with positive air pressure where appropriate (11.1.5.1)

  21. Extractor fans and canopies over cooking or steam areas prevent condensation and vent to the exterior (11.1.5.2)

  22. Fans and exhaust vents are positioned to avoid contamination and seal when closed (11.1.5.3)

  23. A documented equipment purchasing procedure is followed, and equipment specifications are available (11.1.6.1)

  24. Equipment and utensils meet regulations and do not pose a contamination threat (11.1.6.2)

  25. Equipment storage rooms are hygienic, with food contact equipment kept apart where possible (11.1.6.3)

  26. Surfaces in food handling and storage areas are made of materials safe for food (11.1.6.4)

  27. Processing equipment is hygienically designed, with smooth surfaces free from cracks or crevices (11.1.6.5)

  28. Product containers and bins are non-toxic, smooth, and impervious (11.1.6.6)

  29. Bins for inedible material are clearly identified (11.1.6.6)

  30. Vehicles used in processing or storage areas do not create a food safety hazard (11.1.6.7)

  31. Nonconforming equipment is tagged or segregated, and its handling and disposal are recorded (11.1.6.8)

  32. Grounds, storage areas, and equipment are free of debris, with vegetation controlled (11.1.7.1)

  33. External environment controls are monitored and reviewed periodically (11.1.7.1)

  34. Paths, roadways, and loading areas are maintained and drained so water does not pool (11.1.7.2)

  35. External drains are separate from the site drainage system and cleared regularly (11.1.7.2)

  36. Paths from amenities to site entrances are sealed (11.1.7.3)

Section 2 of 14 · 20 questions

11.2.1 To 11.2.3 Maintenance And Calibration

  1. A documented maintenance and repair procedure minimizes contamination risk (11.2.1.1)

  2. Routine maintenance follows a schedule covering buildings and equipment critical to product safety, and is recorded (11.2.1.2)

  3. Equipment failures are documented, reviewed, and added to the maintenance schedule (11.2.1.3)

  4. Supervisors are told before maintenance in production or storage areas and of any product risk (11.2.1.4)

  5. Where possible, maintenance is done outside operating times (11.2.1.4)

  6. Temporary repairs pose no food safety risk and are included in inspections and cleaning (11.2.1.5)

  7. A plan is in place to complete temporary repairs so they do not become permanent (11.2.1.5)

  8. Food-grade lubricant is used on and above food contact equipment, and its use is controlled (11.2.1.6)

  9. Paint in food areas is suitable, in good condition, and not on product contact surfaces (11.2.1.7)

  10. Maintenance staff and contractors follow the site's personnel and process hygiene rules (11.2.2.1)

  11. Contractors are trained in site food safety and hygiene procedures or escorted at all times (11.2.2.2)

  12. Tools and debris are removed after maintenance, and supervisors are told before cleaning and restart (11.2.2.3)

  13. A pre-operational inspection is completed before operations restart after maintenance (11.2.2.3)

  14. A documented calibration procedure covers all monitoring, testing, and inspection equipment (11.2.3.1)

  15. Software used for monitoring and verification is validated as appropriate (11.2.3.1)

  16. Equipment is calibrated against national or international reference standards, or a justified method (11.2.3.2)

  17. Calibration follows regulatory requirements or the manufacturer's recommended schedule (11.2.3.3)

  18. A procedure addresses product affected when equipment is found out of calibration (11.2.3.4)

  19. Calibrated equipment is protected from damage and unauthorized adjustment (11.2.3.5)

  20. A directory of equipment requiring calibration and calibration records are maintained (11.2.3.6)

Section 3 of 14 · 20 questions

11.2.4 Pest Prevention

  1. A documented pest prevention program is implemented, with defined responsibilities and methods (11.2.4.1)

  2. Pest sightings are recorded and trended to target pesticide applications (11.2.4.1)

  3. The program defines prevention methods, elimination methods, and how often pest status is checked (11.2.4.1)

  4. A site map shows the identification, location, number, and type of pest devices (11.2.4.1)

  5. Pest control chemicals are listed, approved by the relevant authority, and have Safety Data Sheets (11.2.4.1)

  6. Personnel are made aware of bait stations and what to do on contact with them (11.2.4.1)

  7. The program defines training for personnel using pest control chemicals and baits (11.2.4.1)

  8. Program effectiveness is measured to verify pest elimination and identify trends (11.2.4.1)

  9. Pest controllers are licensed, use trained and qualified operators, and use only approved chemicals (11.2.4.2)

  10. Pest controllers provide a prevention plan with a site map of devices (11.2.4.2)

  11. Pest controllers report to an authorized person on arrival and after treatments (11.2.4.2)

  12. Pest controllers inspect regularly, act on activity found, and provide written reports (11.2.4.2)

  13. Pest activity risks are analyzed and documented (11.2.4.3)

  14. Trained personnel inspect for pest activity regularly, and inspection and treatment records are kept (11.2.4.3)

  15. No pest activity presents a contamination risk to food, raw materials, or packaging (11.2.4.3)

  16. Pest-contaminated materials are disposed of, the source is resolved, and records are kept (11.2.4.4)

  17. No animals are present in food handling and storage areas (11.2.4.5)

  18. External doors in food areas have self-closers, air curtains, screens, annexes, or dock seals to stop pests (11.2.4.6)

  19. Insect control devices, traps, and baits are positioned so they cannot contaminate product or equipment (11.2.4.7)

  20. No rodenticide bait is used inside storage or processing areas where materials are exposed (11.2.4.7)

Section 4 of 14 · 26 questions

11.2.5 Cleaning And Sanitation (Core Clause)

  1. A documented cleaning program covers all food handling equipment, the environment, and storage areas (11.2.5.1)

  2. The program lists what is cleaned, from walls and drains to amenities, equipment, and utensils (11.2.5.1)

  3. The program defines cleaning methods, frequency, and responsible personnel (11.2.5.1)

  4. Cleaning procedures for food contact surfaces, including CIP, are validated (11.2.5.1)

  5. The program defines how detergent and sanitizer concentrations are checked and how often (11.2.5.1)

  6. The program defines who verifies cleaning effectiveness and how (11.2.5.1)

  7. Equipment and utensils are cleaned after use or at a validated frequency (11.2.5.2)

  8. Clean equipment and utensils are stored to prevent microbial or allergen cross-contact (11.2.5.2)

  9. Detergents and sanitizers are suitable for food manufacturing and labeled as regulations require (11.2.5.3)

  10. A list of approved cleaning chemicals is maintained, and chemical usage is monitored (11.2.5.3)

  11. Safety Data Sheets are available for all detergents and sanitizers (11.2.5.3)

  12. Only trained personnel handle detergents and sanitizers (11.2.5.3)

  13. Detergents and sanitizers are mixed to manufacturer instructions in suitable, labeled containers (11.2.5.4)

  14. Mix concentrations are verified and records are kept (11.2.5.4)

  15. CIP systems pose no chemical contamination risk to materials or product (11.2.5.5)

  16. Critical CIP parameters such as chemical, concentration, contact time, and temperature are monitored and recorded (11.2.5.5)

  17. CIP equipment, including spray balls, is maintained, and modifications are validated (11.2.5.5)

  18. Personnel running CIP are trained (11.2.5.5)

  19. Cleaning tools and equipment are identified, stored, and maintained to prevent contamination (11.2.5.6)

  20. Toilet cleaning tools are never used in processing areas (11.2.5.6)

  21. Designated areas for cleaning utensils and containers do not interfere with production (11.2.5.7)

  22. Racks and containers are provided for storing cleaned utensils as required (11.2.5.7)

  23. Qualified personnel complete pre-operational inspections after cleaning and before production starts (11.2.5.8)

  24. Staff amenities and sanitary facilities are inspected for cleanliness at a defined frequency (11.2.5.9)

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.