Section 1 of 6 · 3 questionsGeneral
What is the number of people that can use the stair tower when the load is evenly distributed?
Does this stair tower serve multiple purposes, such as access and work platform, or is it for access only?
If it is a multipurpose stair tower, have provisions been made for falling object protection?
Section 2 of 6 · 2 questionsStairway Type Ladders (Frame Scaffold Stairs)
Are rest platforms less than 12 feet apart vertically?
Are steps a minimum of 16 inches wide and aligned vertically in each flight?
Section 3 of 6 · 4 questionsSystem Scaffold Stair Tower (Systems Scaffold)
Are stringers installed at a 40 to 60-degree angle?
Is there 18 inches between stair rails?
Are handrails in place on the open sides and ends of each landing?
Is there a landing platform that measures at least 18 inches by 18 inches at each landing?
Section 4 of 6 · 8 questionsGeneral Stair Tower Items
Is the bottom step no more than 24 inches above the scaffold supporting level?
Do all treads and rest platforms or landings have a slip-resistant surface?
Has the scaffold been erected on adequate, firm footing?
For free-standing stair towers, do they meet the 4 to 1 base-to-height ratio as specified in 1926.451(c)?
For stair towers that exceed the 4 to 1 ratio, has the proper form of securing the tower been used (e.g., wall ties, guy wires, bracing, or equivalent means) as specified in 1926.451(c)?
Have the wall ties been installed at a horizontal member that supports the inner and outer legs, as required by 1926.451(c)?
Does the stair tower have a uniform tread depth, with variations within 1/4 inch for each flight of stairs?
Does the stair tower have a uniform riser height, with variations within 1/4 inch for each flight of stairs?
Section 5 of 6 · 6 questionsStair Rails And Handrails Requirements
Do all areas that require handrails have at least a top rail and mid-rail?
Can the top rail serve as a handrail if a separate handrail isn't provided?
Is the handrail installed at a height of at least 28 inches but not more than 37 inches?
Does the stair rail/handrail system have a surface that prevents injuries such as punctures or lacerations to employees?
Are all handrails attached in a manner that does not create a projection hazard?
Do handrails provide an adequate handhold for employees to grasp to avoid falling?
Section 6 of 6 · 4 questionsFalling Object Protection (1926.451(h))
Have falling object hazards been eliminated according to 1926.451?
Have toe boards been installed to prevent falling objects?
Where required, have screens or netting been installed to protect employees from falling objects?
Are toe boards at least 3 1/2 inches tall?
Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.
Free PDF
Download the Scaffold Stair Tower Inspection Checklist
By downloading this checklist you agree to the GoAudits privacy policy and terms of service.
NEW! Try generating a custom checklist with our free AI tool:
Easy inspection app for your digital checklists
- Conduct inspections anytime, anywhere - even offline
- Capture photos as proof of compliance or areas needing attention
- Instantly generate and share detailed reports after the inspections
- Assign & track follow-up tasks, view historical trends on a centralized dashboard