Fire Sprinkler System Inspection Checklist

Use the Fire Sprinkler System Maintenance Checklist for thorough sprinkler system inspections, ensuring systematic checks of pumps through flow tests.

Fire Sprinkler System Inspection Checklist



36 questions in 6 sectionsInteractive preview: try the answers

Section 1 of 6 · 18 questions

System Checks

  1. Is the system free from leaks?

  2. Are all valves in the correct position and secured?

  3. Are all valves and pipes adequately protected from frost damage?

  4. Is pipe insulation undamaged and correctly in place?

  5. Is trace heating cable in good condition?

  6. Is power supply to trace heating live?

  7. Are all sprinklers free from excessive dust, paint, and other issues that may impair operation?

  8. Are all cover plates of concealed sprinklers correctly in position and undamaged?

  9. Has all pipework and hangers been checked for any damage?

  10. Are all electrical connections to pump, flow switches, pressure switches and PDVs free from any visible damage and appear to be in good condition?

  11. Have all flow switches been checked for correct operation?

  12. Are all flow switches correctly providing the necessary signals to the main fire alarm panel?

  13. Are there sufficient test valves installed for flow switch testing and flushing?

  14. Is there a test valve located at the most hydraulically remote point on the system?

  15. Is the water storage tank in good condition?

  16. Has the ball valve been examined and confirmed to be in good condition?

  17. Is the contents gauge operating correctly?

  18. Is the low/high level alarm operating correctly?

Section 2 of 6 · 4 questions

Most Favourable 2 Flow Test

  1. Location

  2. Flow in litres per minute

  3. Pressure in bars

  4. Additional Comments or Recommendations

Section 3 of 6 · 3 questions

Most Remote 1 Flow Test

  1. Location

  2. Flow in litres per minute

  3. Pressure in bars

Section 4 of 6 · 3 questions

Most Remote 2 Flow Test

  1. Location

  2. Flow in litres per minute

  3. Pressure in bars

Section 5 of 6 · 4 questions

Pump No. 1

  1. Pump serial no.

  2. Pump duty

  3. Flow in litres per minute

  4. Pressure in bars

Section 6 of 6 · 4 questions

Pump No. 2

  1. Pump serial no.

  2. Pump duty

  3. Flow in litres per minute

  4. Pressure in bars

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.

Free PDF

Download the Fire Sprinkler System Inspection Checklist

By downloading this checklist you agree to the GoAudits privacy policy and terms of service.

NEW! Try generating a custom checklist with our free AI tool:

Easy inspection app for your digital checklists