Commercial Laundry Safety Inspection Checklist

Utilize this Commercial Laundry Safety Inspection Checklist as a template to audit machine guarding, dryer lint fire controls, and chemical storage.

Commercial Laundry Safety Inspection Checklist



63 questions in 11 sectionsInteractive preview: try the answers

Section 1 of 11 · 5 questions

Soiled Linen Receiving And Sorting

  1. Soiled linen arrives in closed bags or covered carts

  2. Sorting staff wear gloves and aprons suited to the linen being handled

  3. A puncture-resistant sharps container is available at the sorting station

  4. Linen contaminated with blood or body fluids is bagged separately and labeled

  5. Soiled and clean linen follow separate routes with no crossover

Section 2 of 11 · 8 questions

Chemical Storage And Dosing

  1. All chemical containers are labeled with their contents and hazard warnings

  2. Safety data sheets are available at the point of use

  3. Chemicals are stored in bunded areas or on spill pallets

  4. Incompatible chemicals, such as chlorine bleach and acids, are stored apart

  5. Dosing pumps, lines, and fittings show no leaks or cracks

  6. The eyewash station is unobstructed and flushes clean water when tested

  7. A stocked spill kit is located near chemical storage

  8. Staff handling chemicals wear the gloves and eye protection listed on the SDS

Section 3 of 11 · 6 questions

Washers, Tunnel Washers, And Extractors

  1. Washer door interlocks prevent opening while the drum is turning

  2. Emergency stop buttons on each machine work when tested

  3. Belt, pulley, and drive guards are fitted and secured

  4. Lockout points are labeled on every washer and extractor

  5. Lockout devices and tags are available at or near the machines

  6. Tunnel washer loading and transfer zones are guarded, with interlocked access gates

Section 4 of 11 · 10 questions

Dryers And Lint Fire Control

  1. Dryer lint screens have been cleaned for the current shift

  2. No lint has built up behind, above, or around dryers

  3. Dryer exhaust ducts are intact, connected, and free of visible lint buildup

  4. Dryer door switches stop the cycle when the door is opened

  5. Every dryer load finishes with a cool-down cycle before unloading

  6. Dryer water-spray fire suppression is connected with the supply valve open, where fitted

  7. Oil-contaminated linen from spa, kitchen, and massage areas runs on a degreasing wash program

  8. Warm dried linen is spread out to cool, not packed tightly in carts or piles

  9. No dryers are left running unattended at the end of a shift

  10. The area around dryers is free of stored combustible materials

Section 5 of 11 · 6 questions

Ironers, Folders, And Finishing

  1. The flatwork ironer feed guard stops the rolls when tested at shift start

  2. Ironer emergency stop bars or cords work when tested

  3. Folder and stacker access doors stop the machine when opened

  4. Presses require two-hand operation and the controls are not bypassed

  5. Operators near rollers have loose clothing, jewelry, and long hair secured

  6. No guards, interlocks, or safety switches are bypassed or taped over

Section 6 of 11 · 7 questions

Steam, Boiler, And Compressed Air

  1. Steam pipes within reach are insulated or guarded

  2. No steam, condensate, or compressed air leaks are visible or audible

  3. Pressure gauges are readable and show normal operating range

  4. Pressure relief valves are not blocked, capped, or tied down

  5. The boiler room is access-restricted and clear of stored materials

  6. Flues on gas-fired boilers and dryers are intact and connected

  7. Carbon monoxide detection is installed and working where gas equipment runs

Section 7 of 11 · 4 questions

Electrical And Wet Areas

  1. Electrical panels are closed, labeled, and clear of obstructions

  2. Outlets near water sources have ground-fault (GFCI/RCD) protection

  3. Power cords and plugs show no damage, exposed wires, or taped repairs

  4. No extension cords are used as permanent power supplies for machines

Section 8 of 11 · 3 questions

Heat And Ventilation

  1. Production floor temperature is within the limit set in the site heat stress plan

  2. Ventilation fans and make-up air units are running

  3. Cool drinking water is available on the production floor

Section 9 of 11 · 5 questions

Carts, Manual Handling, And Floors

  1. Laundry carts and cages have working wheels and no broken frames or sharp edges

  2. Carts are not loaded above their rim or marked capacity

  3. Spring-loaded cart bases or other lifting aids are available and in use

  4. Floors are dry, or wet areas are signed and fitted with anti-slip matting

  5. Aisles and walkways are clear of carts, bags, and loose linen

Section 10 of 11 · 4 questions

Fire And Emergency

  1. Fire extinguishers are mounted, accessible, and within their service date

  2. Fire exits are unlocked, clearly marked, and unobstructed

  3. Stored linen is kept below the required clearance from sprinkler heads

  4. Emergency lighting and exit signs are illuminated

Section 11 of 11 · 5 questions

Records And Training (Desk Review)

  1. Operators have documented training for each machine they run

  2. Lockout/tagout training is current for maintenance staff and machine operators

  3. Dryer exhaust duct cleaning is recorded at the scheduled interval

  4. Daily ironer and dryer safety device tests are recorded

  5. Boiler and pressure vessel inspection certificates are current

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.

Free PDF

Download the Commercial Laundry Safety Inspection Checklist

By downloading this checklist you agree to the GoAudits privacy policy and terms of service.

NEW! Try generating a custom checklist with our free AI tool:

Easy inspection app for your digital checklists