Architectural Checklist

Use this Architectural Checklist for inspections in construction phase, to verify execution compliance with approved plans and specifications.

Architectural Checklist



73 questions in 13 sectionsInteractive preview: try the answers

Section 1 of 13 · 5 questions

Pre-Inspection & Documentation

  1. Are the latest approved drawings, specs, and RFIs on-site?

  2. Has the builder posted a building permit and mandatory safety signage?

  3. Are all shop drawings and material submittals architect-approved?

  4. Have change orders affecting today’s scope been issued and signed?

  5. Is the construction schedule up to date and displayed on site?

Section 2 of 13 · 6 questions

Site Safety & Environmental Controls

  1. Is the site fenced, with clear access control points?

  2. Are walkways clear of trip hazards and properly illuminated?

  3. Are fall protection systems installed where needed?

  4. Is PPE (hard hats, boots, vests, goggles) worn by all personnel?

  5. Are erosion-control and storm-water measures functioning?

  6. Is dust, noise, and debris containment adequate for neighbors?

Section 3 of 13 · 6 questions

Foundations & Substructure

  1. Do footing dimensions match structural drawings?

  2. Is rebar size, spacing, and cover verified before the concrete pour?

  3. Are foundation walls plumb and free of honeycombing?

  4. Are waterproofing membranes fully bonded and lap-sealed?

  5. Has perimeter drainage (weep holes, drain tile) been installed?

  6. Are slab depressions and block-outs located per plan?

Section 4 of 13 · 6 questions

Structural Frame

  1. Are column and beam sizes correct and labeled?

  2. Are steel members free of visible corrosion and damage?

  3. Are welds inspected and marked as accepted by the engineer?

  4. Are anchor bolts set to correct projection and alignment?

  5. Are temporary bracing and shoring installed per the engineering plan?

  6. Has concrete strength been field-tested and results logged?

Section 5 of 13 · 6 questions

Building Envelope

  1. Do exterior wall substrates align vertically and horizontally?

  2. Is the weather-resistive barrier continuous, taped, and undamaged?

  3. Are window and door rough openings flashed on all four sides?

  4. Are air-sealing details around penetrations executed per spec?

  5. Is insulation thickness and placement compliant with drawings?

  6. Are façade materials (brick, cladding, panels) installed plumb and level?

Section 6 of 13 · 6 questions

Roof Assembly

  1. Is roof sheathing properly fixed and gaps within tolerance?

  2. Are underlayment and membranes lapped per the manufacturer’s guide?

  3. Are parapet caps and flashing installed with a positive slope?

  4. Are roof penetrations (vents, skylights) properly crickets and counter-flashed?

  5. Has the roof drain test confirmed positive drainage?

  6. Is rooftop equipment mounted on curbs with isolation pads?

Section 7 of 13 · 6 questions

Interior Partitions & Finishes

  1. Are stud locations and gauges per framing schedule?

  2. Are partitions plumb, straight, and securely anchored at the top and base?

  3. Is fire-rated board installed where required, with joints taped?

  4. Are door frames set square and grouted (if hollow metal)?

  5. Are finish materials (tile, flooring) acclimated before installation?

  6. Is wall/floor transition detailing consistent and clean?

Section 8 of 13 · 5 questions

Accessibility & Code Compliance

  1. Are doorway clear widths and hardware heights compliant with ADA?

  2. Is the ramp slope no steeper than 1:12 and the landing level?

  3. Are visual and tactile signage placeholders in the correct positions?

  4. Are toilet room layouts meeting grab-bar and clearance specs?

  5. Is the required turning radius maintained in corridors and rooms?

Section 9 of 13 · 6 questions

MEP Coordination (Architectural Interface)

  1. Are slab and wall penetrations sleeved and fire-caulked?

  2. Are ceiling heights unobstructed by ductwork or piping drops?

  3. Are diffusers, grilles, and lights centered as shown on RCP?

  4. Are electrical boxes set flush to finish the plane?

  5. Is the plumbing fixture rough-in at the correct height and location?

  6. Are roof penetrations properly cricketed and sealed?

Section 10 of 13 · 6 questions

Fire & Life-Safety

  1. Are fire-rated assemblies labeled and intact after penetrations?

  2. Are fire-door frames tagged and installed in the correct locations?

  3. Are rated shafts continuous with no open joints or gaps?

  4. Is sprinkler head coverage free of obstructions?

  5. Are exit signs and egress lighting provisions in place?

  6. Is stair pressurization ductwork installed per the life-safety plan?

Section 11 of 13 · 5 questions

Sustainability & Energy Features

  1. Are specified low-VOC materials stored per manufacturer guidelines?

  2. Are daylighting controls roughed in near the building perimeter?

  3. Is continuous insulation installed with no thermal bridges?

  4. Are roof solar-ready conduits and mounts located per plan?

  5. Has waste separation for recycling been implemented on-site?

Section 12 of 13 · 5 questions

Quality & Workmanship

  1. Are surface alignments within tolerance (±3 mm over 3 m)?

  2. Is mortar or adhesive squeeze-out cleaned from joints?

  3. Are exposed fasteners evenly spaced and consistent?

  4. Are moisture readings of wood products within allowable limits?

  5. Have mock-ups been approved and matched in production work?

Section 13 of 13 · 5 questions

Punch-List & Close-Out

  1. Are all observed deficiencies logged with location and photo?

  2. Have corrective actions been assigned to responsible trade?

  3. Is the O&M manual compilation in progress and on schedule?

  4. Are warranties and certificates collected for installed systems?

  5. Has the architect issued a preliminary Certificate of Substantial Completion?

Checklist by GoAudits. This checklist is an example: we do not guarantee compliance with the laws applicable to your territory or industry. Seek professional advice to adapt it to your workplace or jurisdiction.

Free PDF

Download the Architectural Checklist

By downloading this checklist you agree to the GoAudits privacy policy and terms of service.

NEW! Try generating a custom checklist with our free AI tool:

Easy inspection app for your digital checklists