Building Commissioning Checklist

Use this Building Commissioning Checklist to verify HVAC, electrical, plumbing, and envelope systems are correctly installed and operational before use.

Building Commissioning Checklist



HVAC

1. Have the thermometers and gauges been checked?


Photo Comment

2. Has the vibration isolation been inspected?


Photo Comment

3. Has the steam condensate system been evaluated?


Photo Comment

4. Have the hot water heating systems been examined?


Photo Comment

5. Have the computer room HVAC systems been tested?


Photo Comment

6. Has the chemical water treatment system been reviewed?


Photo Comment

7. Have the chillers been inspected?


Photo Comment

8. Have the cooling towers been assessed?


Photo Comment

9. Has the condenser water system been checked?


Photo Comment

10. Have the air terminal unit systems (VAV, PIU, etc.) been evaluated?


Photo Comment

11. Have the humidifiers been tested?


Photo Comment

12. Have the duct silencers been inspected?


Photo Comment

13. Have the dampers been reviewed?


Photo Comment

14. Have the variable frequency drives and motors been checked?


Photo Comment

15. Has the air distribution system been assessed?


Photo Comment

16. Have the exhaust air systems been examined?


Photo Comment

17. Have the trend logs been reviewed?


Photo Comment

18. Has the network communication been tested?


Photo Comment

19. Has the test and balance verification been completed?


Photo Comment

20. Has the refrigeration equipment and controls been inspected?


Photo Comment

21. Has the chilled water system been evaluated?


Photo Comment
Building Envelope

1. Has the roofing system been inspected for water-proofing, insulation, roof membrane, rain and ice shield, pitch, coping, flashing, curbs for mechanical equipment, downspouts, drains, and scuppers?


Photo Comment

2. Has the exterior skin been evaluated, including curtain wall, storefront, masonry, brick/stone veneers, precast panels, metal panels, stucco/EIFS, and siding?


Photo Comment

3. Have the walls been checked for vapor barriers, insulation, mortar nets, weeps, joints, sealants, and masonry ties?


Photo Comment

4. Has the slab on grade been inspected for vapor barriers, waterproofing, drainage, and foundation drains?


Photo Comment

5. Have the doors and windows been reviewed for sealants, mechanical operation, sills, flashing, end dams, and hardware?


Photo Comment

6. Have water tests, mockups, wind loads, and thermal infiltration been conducted?


Photo Comment

7. Have the special design features (dome, cornice, canopy, skylight, etc.) been assessed?


Photo Comment
Electrical

1. Has the service switchgear been inspected?


Photo Comment

2. Has the emergency power system been tested?


Photo Comment

3. Have the generators been checked?


Photo Comment

4. Have the lighting controls (scheduled activators and occupancy sensors) been reviewed?


Photo Comment

5. Have the daylight dimming controls been evaluated?


Photo Comment

6. Has the exterior lighting been inspected?


Photo Comment

7. Has the interior lighting been examined?


Photo Comment

8. Have the switchboards been checked?


Photo Comment

9. Have the distribution panel boards been reviewed?


Photo Comment

10. Have the motor control centers been inspected?


Photo Comment

11. Has the power monitoring and metering system been evaluated?


Photo Comment

12. Have the transient voltage surge suppressors been tested?


Photo Comment

13. Have the variable frequency and speed drives been reviewed?


Photo Comment

14. Has the grounding and ground fault system been inspected?


Photo Comment

15. Have the overcurrent protective devices been checked?


Photo Comment

16. Have the low-voltage busways been assessed?


Photo Comment

17. Has the thermographic survey been completed?


Photo Comment

18. Has the paging system and security been reviewed?


Photo Comment

19. Have the ATS auto-transfer switches been tested?


Photo Comment

20. Have the bus duct and tap devices been inspected?


Photo Comment

21. Has the fire alarm and smoke detectors system been checked?


Photo Comment

22. Have the standby and emergency power systems been reviewed?


Photo Comment

23. Has the emergency lighting been assessed?


Photo Comment

24. Have the security systems been inspected?


Photo Comment

25. Has the electrical primary voltage system been evaluated?


Photo Comment

26. Have the transformers been checked?


Photo Comment
Plumbing

1. Have the cleaning/flushing water systems been inspected?


Photo Comment

2. Have the trap primers been reviewed?


Photo Comment

3. Has the vibration isolation been checked?


Photo Comment

4. Has the high-purity water system been evaluated?


Photo Comment

5. Has the deionized water system been tested?


Photo Comment

6. Have the thermometers and gauges been checked?


Photo Comment

7. Have the irrigation systems been inspected?


Photo Comment

8. Has the water filtration system (general use) been reviewed?


Photo Comment

9. Have the domestic hot water systems been evaluated?


Photo Comment

10. Have the tempered water systems been checked?


Photo Comment

11. Have the fuel oil/gas systems been inspected?


Photo Comment

12. Have the potable water and booster pump systems and electors been reviewed?


Photo Comment

13. Have the backflow preventers and relief valves been tested?


Photo Comment